Three-Phase Grid-Tied Inverter · 50-70 kW
MAC 50-70KTL3-X2 LV&MV Grid-Tied Inverter
Models: MAC 50KTL3-X2 LV / MAC 60KTL3-X2 LV / MAC 66KTL3-X2 MV / MAC 70KTL3-X2 MV
A 50-70 kW three-phase grid-tied inverter platform for commercial and industrial PV systems. Available in low-voltage (230/400 V) and medium-voltage (277/480 V) variants with 3 MPPT inputs, 1100 V maximum DC voltage, 98.80% maximum efficiency and IP66-rated outdoor protection.
50-70 kW
Rated output
3
MPPT inputs
98.80%
Max efficiency
IP66
Protection
Product Overview
The MAC 50-70KTL3-X2 LV&MV series is a three-phase grid-tied inverter platform available in four models from 50 kW to 70 kW rated output. Low-voltage variants (50K and 60K) operate at 230/400 V with a 340-440 VAC output range, while medium-voltage variants (66K and 70K) operate at 277/480 V with a 425-540 VAC output range.
Each model uses 3 MPPT inputs with up to 64 A per MPPT and 4 strings per MPPT on the first tracker plus 3 strings on MPPTs 2 and 3. The maximum DC input voltage is 1100 V with an MPPT operating range of 200-1000 V. Full-load MPPT voltage is 600-850 V for LV models and 650-850 V for MV models. Maximum efficiency reaches 98.80% with 99.90% MPPT efficiency.
Key Features
- Three-phase grid-tied inverter, 50-70 kW rated output
- 3 MPPT inputs with up to 64 A per MPPT
- 1100 V maximum DC input voltage
- 98.80% maximum efficiency, 99.90% MPPT efficiency
- IP66 protection for outdoor installation
- Smart air cooling
- Transformerless design
- DC reverse-polarity and insulation-resistance protection
- Type II DC and AC surge protection
- RCD (GFCI) and AC short-circuit protection
- String-level monitoring
- Anti-PID and AFCI optional
- OLED + LED display with WiFi / APP
- 4000 m maximum operating altitude (2000 m without derating)
- 5-year standard warranty, 10-year optional
Technical Specifications
DC Input (PV)
| Parameter | MAC 50KTL3-X2 LV | MAC 60KTL3-X2 LV | MAC 66KTL3-X2 MV | MAC 70KTL3-X2 MV |
|---|---|---|---|---|
| Maximum input power | 75,000 W | 90,000 W | 99,000 W | 105,000 W |
| Maximum input voltage | 1,100 V | 1,100 V | 1,100 V | 1,100 V |
| Start-up voltage | 250 V | 250 V | 250 V | 250 V |
| MPPT operating range / rated input voltage | 200-1,000 V / 600 V | 200-1,000 V / 600 V | 200-1,000 V / 700 V | 200-1,000 V / 700 V |
| Full-load MPPT voltage range | 600-850 V | 600-850 V | 650-850 V | 650-850 V |
| Maximum input current per MPPT | 64 A / 48 A / 48 A | 64 A / 48 A / 48 A | 64 A / 48 A / 48 A | 64 A / 48 A / 48 A |
| Number of MPPTs / strings per MPPT | 3 / 4+3+3 | 3 / 4+3+3 | 3 / 4+3+3 | 3 / 4+3+3 |
AC Output
| Parameter | MAC 50KTL3-X2 LV | MAC 60KTL3-X2 LV | MAC 66KTL3-X2 MV | MAC 70KTL3-X2 MV |
|---|---|---|---|---|
| Rated output power | 50,000 W | 60,000 W | 66,000 W | 70,000 W |
| Maximum output apparent power | 55,500 VA | 66,600 VA | 73,300 VA | 77,700 VA |
| Rated output voltage | 230 V / 400 V | 230 V / 400 V | 277 V / 480 V | 277 V / 480 V |
| Output voltage range | 340-440 VAC | 340-440 VAC | 425-540 VAC | 425-540 VAC |
| Rated grid frequency / range | 50/60 Hz ±5 Hz | 50/60 Hz ±5 Hz | 50/60 Hz ±5 Hz | 50/60 Hz ±5 Hz |
| Maximum AC output current | 84.4 A | 101.3 A | 88.2 A | 93.6 A |
| Power factor | 1 | 1 | 1 | 1 |
| Power factor adjustment range | 0.8 leading – 0.8 lagging | 0.8 leading – 0.8 lagging | 0.8 leading – 0.8 lagging | 0.8 leading – 0.8 lagging |
| THDi | <3% | <3% | <3% | <3% |
| AC connection type | 3W+N+PE | 3W+N+PE | 3W+PE | 3W+PE |
Efficiency
| Maximum efficiency | 98.80% |
| China efficiency | 98.50% |
| MPPT efficiency | 99.90% |
Protection
| DC reverse-polarity protection | Available |
| DC switch | Available |
| DC surge protection | Type II |
| Insulation-resistance monitoring | Available |
| RCD (GFCI) | Available |
| AC short-circuit protection | Available |
| AC surge protection | Type II |
| String monitoring | Available |
| Anti-PID function | Optional |
| AFCI (arc-fault circuit interrupter) | Optional |
General Data and Certification
| Dimensions (W × H × D) | 680 × 508 × 281 mm |
| Weight | 58 kg |
| Operating temperature range | -30 °C to +60 °C |
| Maximum operating altitude | 4,000 m (2,000 m without derating) |
| Night-time self-consumption | <1 W |
| Topology | Transformerless |
| Cooling | Smart air cooling |
| Protection rating | IP66 |
| Relative humidity | 0-100%, non-condensing |
| DC input connector | H4 / MC4 (optional) |
| AC output connector | OT compression terminal |
| Display | OLED + LED / WiFi / APP |
| Communication | USB / RS485 available; WiFi / GPRS / 4G optional |
| Warranty | 5 years standard / 10 years optional |
| Certification | CQC, EN 61000-3, EN 61000-6, EN/IEC 62109-1, EN/IEC 62109-2, IEC 60529 |
Applications
The MAC 50-70KTL3-X2 LV&MV series is designed for commercial and industrial rooftop PV installations requiring high efficiency, flexible low-voltage or medium-voltage grid connection and IP66 outdoor durability.
- Commercial rooftop PV systems
- Industrial ground-mounted PV plants
- Carport and canopy solar installations
- Low-voltage 230/400 V grid networks (LV models)
- Medium-voltage 277/480 V grid networks (MV models)
OEM & Custom Requirements
Project supply and private-label requirements can be confirmed against the standard MAC 50-70KTL3-X2 platform. Share the destination grid code, voltage variant and installation environment.
- Private-label enclosure and documentation
- Grid-code configuration for the target market
- Manual localisation for the destination country
- Packaging and delivery planning
Need a project-specific quote?
Send us the required voltage variant, destination grid code and installation environment. We will confirm the model, documentation package and delivery schedule.