66QL6-BDV Series

66QL6-BDV Series

66QL6-BDV Series

650-670W N-type TOPCon bifacial dual glass solar module, model JKM650-670N-66QL6-BDV-F2

N-Type TOPCon · Bifacial Dual Glass

650–670W N-Type TOPCon Bifacial Solar Module

Model: JKM650-670N-66QL6-BDV-F2 · 66QL6-BDV Series

A 66-cell N-type TOPCon module built with dual 2.0 mm glass and an anodized aluminium frame. It delivers 650–670 W front-side power, up to 746 W bifacial output under BNPI conditions and up to 24.80% module efficiency for utility-scale, commercial rooftop and ground-mount projects.

650–670 W

Maximum power

24.80%

Maximum efficiency

85 ± 5%

Bifaciality

30 years

Linear power warranty

Product Overview

The 66QL6-BDV uses an N-type TOPCon cell platform with 264 cells in a 66 × 4 layout. The bifacial dual-glass structure captures front-side irradiance and rear-side reflected light, while the low temperature coefficients help maintain output in high-temperature operating conditions.

The module is supplied in five power classes from 650 W to 670 W, with a 1500 VDC maximum system voltage, IP68 junction box and Class II safety rating. Connector type, cable length and packaging can be confirmed against each project requirement.

Key Features

  • N-type TOPCon cell platform with 264 cells (66 × 4)
  • Bifacial dual-glass construction with 85 ± 5% bifaciality
  • Up to 24.80% module efficiency across the 650–670 W range
  • Low Pmax temperature coefficient of -0.26%/°C
  • IP68 junction box, Class II safety and Class C IEC fire rating
  • 1500 VDC maximum system voltage and 35 A maximum series fuse
  • 12-year product warranty and 30-year linear power warranty
  • JK03M / JK03M2 connectors; MC4-EVO2 available on request

Technical Specifications

Electrical Characteristics at STC

Parameter650655660665670
Maximum power – Pmax (Wp)650655660665670
Optimum operating voltage – Vmp (V)42.5742.7042.8342.9643.09
Optimum operating current – Imp (A)15.2715.3415.4115.4815.55
Open-circuit voltage – Voc (V)50.2650.4450.6250.8050.98
Short-circuit current – Isc (A)15.9816.0416.1016.1616.22
Module efficiency (%)24.0624.2524.4324.6224.80
Bifaciality85 ± 5%
Power output tolerance0 ~ +3%
Temperature coefficient of Pmax-0.26%/°C
Temperature coefficient of Voc-0.24%/°C
Temperature coefficient of Isc0.046%/°C
STC: irradiance 1000 W/m², cell temperature 25 °C, air mass AM 1.5.

Bifacial Output at BNPI

Parameter650655660665670
Maximum power – Pmax (W)724729735741746
Optimum operating voltage – Vmp (V)42.5242.6942.8643.0343.20
Optimum operating current – Imp (A)17.0417.1017.1717.2317.30
Open-circuit voltage – Voc (V)50.3850.5650.7450.9251.10
Short-circuit current – Isc (A)17.8017.8717.9418.0018.07
BNPI: front irradiance 1000 W/m², rear irradiance 135 W/m², ambient temperature 25 °C, air mass AM 1.5.

Mechanical & Structural Parameters

Cell typeN-type monocrystalline
Cell configuration264 cells (66 × 4)
Module dimensions2382 × 1134 × 30 mm
Weight32.5 kg
Front glass2.0 mm high-transmission coated glass
Back glass2.0 mm semi-tempered glass
FrameAnodized aluminium alloy
Junction boxIP68
Safety classClass II
IEC fire classClass C
Connector typeJK03M / JK03M2 / other; MC4-EVO2 available on request
Output cable4.0 mm²; (+) 600 mm, (-) 400 mm; customizable

Operating Conditions

Maximum system voltage1500 VDC (IEC)
Maximum series fuse rating35 A
Operating temperature – T98≤ 70 °C
Bifaciality coefficientsφVoc 98 ± 5%; φIsc 85 ± 5%; φPmax 85 ± 5%
Product warranty12 years
Linear power warranty30 years
Power degradation1% in the first year; 0.35% per year thereafter
Short-term tolerance is allowed up to 85 °C; higher-temperature applications require IEC TS 63126 testing.

Packaging

Pallet dimensions2396 × 1110 × 1251 mm
13 m flatbed truck36 pcs/pallet; 20 pallets/truck; 720 pcs/truck
17.5 m flatbed truck36 pcs/pallet; 25 pallets/truck; 900 pcs/truck
Packing quantities are the standard configuration shown in the current datasheet. Confirm the final pallet and container plan with the sales team before booking.

Applications

The bifacial dual-glass format is suited to projects that can use rear-side gain from reflected light, including utility-scale ground mounts, commercial and industrial rooftops, distributed generation and solar farms with elevated mounting structures.

  • Utility-scale ground-mounted solar farms
  • Commercial and industrial rooftop projects
  • Distributed generation with bifacial racking
  • Projects using high-albedo ground surfaces

OEM & Custom Requirements

We support project supply and private-label requirements around the standard 66QL6-BDV platform. Share the target wattage class, quantity, connector preference and destination port, and we will confirm the available configuration before quotation.

  • OEM branding on the frame, label and carton
  • Module power class selection from 650 W to 670 W
  • Connector type and cable length to project specification
  • Pallet and packaging configuration for flatbed or container shipment

Need a project-specific quote?

Send us the required wattage class, quantity, destination port and preferred connector. We will confirm module availability, packing and lead time against your project schedule.